Hi,
I just did a fresh setup of weewx + interceptor driver for a garni 3055
(Talks ecowitt)
The weather station gives 3 fields that seem to be problematic:
vpd; Vapor Pressure Deficit? So far it's always 0 so not sure if it
actually logs anything)
wh40batt (recognized but not logged anywhere); which i think is the rain
meter battery level.
wh80batt; which is the battery level for the uv / wind meter combo.
Maybe someone can comment on if 'vpd' is worth tracking but i would like to
map the wh40batt to the 'rainBatteryStatus' field and the wh80batt to the
'windBatteryStatus' so i can keep track of the battery level.
(also open to suggestions if something else is better)
I have tried:
[Interceptor]
-stuff-
[[sensor_map_extensions]]
wh40batt = rainBatteryStatus
wh80batt = windBatteryStatus
and literally changing the interceptor.py's label map:
'wh40batt': 'rainBatteryStatus',
'wh80batt': 'windBatteryStatus',
Neither seems to be working, but it did stop with the unknown parameter
error.
weewx logs to mysql so messing with the db is easy.
--
You received this message because you are subscribed to the Google Groups
"weewx-user" group.
To unsubscribe from this group and stop receiving emails from it, send an email
to [email protected].
To view this discussion visit
https://groups.google.com/d/msgid/weewx-user/6c63d17b-4a91-44e3-a859-0b976e0e8f40n%40googlegroups.com.