Thanks for all your hints. I'll switch over to Ian's version. I guess that one must stop a running weewx instance using Ecowitt_HTTP before using weectl to install ecowittGateway, correct? Otherwise tweaks done by ecowittGateway during installation to /etc/weewx.conf might interfere with the active running weewx.
Regards, Michael Dr__Bob schrieb am Dienstag, 17. November 2026 um 20:14:37 UTC+1: > And Ian’s version does fix the issue of weewx crashing on network errors. > > On Sunday, November 15, 2026 at 11:43:39 PM UTC-8 [email protected] > wrote: > >> The driver with the IMHO best support for both, the ecowitt devices and >> the driver itself, is currently this one: >> https://github.com/Millardiang/weewx-ecowittGateway >> I highly recommend you to look into it. >> >> Michael Waldor schrieb am Montag, 16. November 2026 um 08:15:02 UTC+1: >> >>> Just yesterday the ecowitt driver did crash unexpectedly after many >>> weeks of runtime. It did not recover automatically - instead I had to >>> restart weewx manually. See below the error messages >>> (weewx-ecowitt_http_updatedriver_0.3.4.zip from WernerKr - I'm aware of >>> 0.3.5, but it does add sensors, no changes at locations of crash). As far >>> as I can tell there was no network problem at that time (OK, there was an >>> automatic channel switch for 5GHz at 20:53:02, but that happens regularly). >>> Please note the time gap - first errors are recovered at 19:46, failure was >>> around 1h later >>> >>> Nov 15 19:41:50 imurr9 weewxd[577]: ERROR user.ecowitt_http: URL - >>> Failed to get device data on attempt 1 of 3 >>> Nov 15 19:41:50 imurr9 weewxd[577]: ERROR user.ecowitt_http: **** >>> <urlopen error timed out> >>> Nov 15 19:41:50 imurr9 weewxd[577]: ERROR user.ecowitt_http: Unable to >>> obtain live sensor data >>> Nov 15 19:41:51 imurr9 weewxd[577]: CRITICAL __main__: Caught >>> WeeWxIOError: >>> Nov 15 19:41:51 imurr9 weewxd[577]: CRITICAL __main__: **** Waiting >>> 60.0 seconds then retrying... >>> Nov 15 19:42:58 imurr9 weewxd[577]: ERROR user.ecowitt_http: URL - >>> Failed to get device data on attempt 1 of 3 >>> Nov 15 19:42:58 imurr9 weewxd[577]: ERROR user.ecowitt_http: **** >>> HTTP Error 404: Not Found >>> Nov 15 19:46:20 imurr9 weewxd[577]: ERROR weewx.restx: StationRegistry: >>> Failed to publish record 2026-11-15 19:45:00 CET (1794768300): HTTP Error >>> 429: TOO MANY REQUESTS >>> >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> Traceback (most recent call last): >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> File "/etc/weewx/bin/user/ecowitt_http.py", line 7074, in run >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> self.client.collect() >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> File "/etc/weewx/bin/user/ecowitt_http.py", line 6923, in collect >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> queue_data = self.get_current_data() >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> File "/etc/weewx/bin/user/ecowitt_http.py", line 7016, in >>> get_current_data >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> curr_data.update(self.device.get_sensors_data()) >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> File "/etc/weewx/bin/user/ecowitt_http.py", line 13450, in >>> get_sensors_data >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> sensors_data = self.api.get_sensors_info() >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> File "/etc/weewx/bin/user/ecowitt_http.py", line 7300, in >>> get_sensors_info >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> page_2 = self.request('get_sensors_info', data={'page': 2}) >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> File "/etc/weewx/bin/user/ecowitt_http.py", line 7198, in request >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> resp = resp.replace(old, new) >>> Nov 15 20:53:21 imurr9 weewxd[577]: CRITICAL user.ecowitt_http: **** >>> UnboundLocalError: local variable 'resp' referenced before assignment >>> >>> >>> Doc Matt schrieb am Montag, 28. September 2026 um 18:57:56 UTC+2: >>> >>>> FWIW I've seen crashes in ecowitt_http for the following reasons: >>>> >>>> - no SD card installed in GW3000 >>>> - gateway is currently rebooting and does not respond in time >>>> - gateway has no upstream sensor data (battery gone on the weather >>>> station?), so there's no catchup data file for "today". This one hits just >>>> after midnight, following any upstream outage. >>>> >>>> The systemd retry workaround seems effective, but there's a lot of >>>> holes to fall into here. >>>> >>>> On Wednesday, August 5, 2026 at 2:45:47 PM UTC+1 matthew wall wrote: >>>> >>>>> >>>>> >>>>> > On Aug 5, 2026, at 02:18, 'Michael Waldor' via weewx-user < >>>>> [email protected]> wrote: >>>>> > >>>>> > Of course the driver EcowittHttp relies on a working network >>>>> connection. But during boot weewx might be started too early before >>>>> network >>>>> is up. In that exceptional case weewx will crash: >>>>> > >>>>> > CRITICAL __main__: **** File "/etc/weewx/bin/user/ecowitt_http.py", >>>>> line 6775> CRITICAL __main__: **** if self.collector.device.model is not >>>>> None: CRITICAL __main__: **** File "/etc/weewx/bin/user/ecowitt_http.py", >>>>> line 13722> CRITICAL __main__: **** version_data = self.api.get_version() >>>>> CRITICAL __main__: **** File "/etc/weewx/bin/user/ecowitt_http.py", line >>>>> 7224> CRITICAL __main__: **** raise DeviceIOError(f"Failed to obtain >>>>> 'get_version' data: {e}")> CRITICAL __main__: **** >>>>> user.ecowitt_http.DeviceIOError: Failed to obtain 'get> CRITICAL >>>>> __main__: >>>>> **** Exiting. >>>>> > >>>>> > I myself have resolved that issue on my raspberry pi4 by enabling >>>>> "wait on network" before starting other services. >>>>> >>>>> this behavior is by design. when a driver fails during initialization, >>>>> it is *supposed* to fail hard - that way you can figure out what is >>>>> happening and fix it. >>>>> >>>>> in this particular case, the solution is to either set >>>>> "loop_on_init=True", or fix your system configuration so that networking >>>>> is >>>>> established before weewx starts up. >>>>> >>>>> details: >>>>> >>>>> there are some drivers and weewx installations that never use >>>>> networking. in those cases, they do not need the system to have >>>>> networking >>>>> before weewx starts. >>>>> >>>>> there are some installations of the ecowitt driver that are bound to a >>>>> specific ip address, others use the discovery option to automatically >>>>> find >>>>> an ecowitt station on the network. there are some installations that have >>>>> multiple weewx instances, each of which talks to a different ecowitt >>>>> station. this requires binding to an address instead of discovery. in the >>>>> binding case, it is useful to have the driver fail hard when it cannot >>>>> contact the ecowitt station - that indicates that the ip address of the >>>>> station has changed, or the station is not online, or ... >>>>> >>>>> >>>>> >>>>> -- You received this message because you are subscribed to the Google Groups "weewx-user" group. To unsubscribe from this group and stop receiving emails from it, send an email to [email protected]. To view this discussion visit https://groups.google.com/d/msgid/weewx-user/d20660a9-ff9d-4fa6-9693-1fdfe93d0b4an%40googlegroups.com.
