Yes, a "normal" scf cycle does of course NOT change atomic positions nor 
lattice parameters.

With MSR1a instead if MSR1 in case.inm   you can optimize the atomic positions 
(if allowed by symmetry).

Lattice parameters must be modified "manually" (or by a script like 
optimize.job).


Am 09.06.2013 01:51, schrieb Minghao Zhang:
Dear professor,

We are doing the example running in the user guide through GUI, and everything 
is all right. However I have a question about the calculation sequence. For a 
specific
calculation, if I do not do the Mini for atom positions and volume 
optimizations for the unit cell, does that mean the unit cell parameters a, b, 
c,etc and the position of
atoms will never change even after the scf running and properties calculation?

Best regards,

--
Minghao, Zhang, Graduate Student.
Department of NanoEngineering
University of California, San Diego
SME Building, room 242C
9500 Gilman Drive
La Jolla, CA 92093
Cell: 858-956-9058
e-mail: miz...@eng.ucsd.edu <mailto:kjcarr...@ucsd.edu>
Group website: http://ne.ucsd.edu/smeng/


_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


--
-----------------------------------------
Peter Blaha
Inst. Materials Chemistry, TU Vienna
Getreidemarkt 9, A-1060 Vienna, Austria
Tel: +43-1-5880115671
Fax: +43-1-5880115698
email: pbl...@theochem.tuwien.ac.at
-----------------------------------------
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to