Dear Elias, I also same problem in the older version. It was related also in the number of wannier function.
Regards wasim On Mon, May 12, 2014 at 2:07 PM, Elias Assmann <elias.assm...@gmail.com>wrote: > On 05/09/2014 10:27 PM, Kefeng Wang wrote: > >> Dear All, >> >> I tried to follow the SrVO3 example in wien2wannier 1.0 beta2 and >> Wannier90 1.2. Everything went well until the command ‘x wplot –wf –m” >> failed. The error message is “forrtl: severe (59): list-directed I/O >> syntax error, unit -5, file Internal List-Directed Read”. Before that, I >> compared the bandstructures and it is good. Could anybody help me out? >> > > Sorry, I see I was a bit too fast there -- it is an “internal read”, i.e. > it is trying to read from a string. My guess is that it is the ‘-m’ in > your command line. The option is ‘-wf M’ where M is a number; ‘-m’ is not > a valid option. > > > Elias > > > _______________________________________________ > Wien mailing list > Wien@zeus.theochem.tuwien.ac.at > http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien > SEARCH the MAILING-LIST at: http://www.mail-archive.com/ > wien@zeus.theochem.tuwien.ac.at/index.html >