Ok.
Perhaps I was wrong in understanding that MSR1a could be started without
first using MSR1.
Now I have started a scf calculation with MSR1 and low charge tolerance. If
it converges then I will restart it with MSR1a.
Cheers,

On 16 December 2014 at 15:05, Lyudmila Dobysheva <[email protected]> wrote:
>
> On 16.12.2014 13:51, Shafqat Hussain Shah wrote:
>
>> In my case when I am using
>> MSR1a from the start I have following first and last twenty iterations
>>
>
> And again: why you are using MSR1a from the start? This is wrong. Your
> atoms are moved in the first iterations to an absolutely wrong positions,
> and then very slow return to correct ones.
>
>
> Best regards
>   Lyudmila Dobysheva
> ------------------------------------------------------------------
> Phys.-Techn. Institute of Ural Br. of Russian Ac. of Sci.
> 426001 Izhevsk, ul.Kirova 132
> RUSSIA
> ------------------------------------------------------------------
> Tel.:7(3412) 218988(office), 722529(Fax)
> E-mail: [email protected], [email protected] (office)
>         [email protected] (home)
> Skype:  lyuka17 (home), lyuka18 (office)
> http://fti.udm.ru/content/view/25/103/lang,english/
> ------------------------------------------------------------------
> _______________________________________________
> Wien mailing list
> [email protected]
> http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
> SEARCH the MAILING-LIST at:  http://www.mail-archive.com/
> [email protected]/index.html
>


-- 