You are running out of memory.
You cannot run 70x30x30 unit cells on a PC and in sequential mode.

Am 22.12.2015 um 22:00 schrieb Hu, Wenhao:
Hi, All:

I met a problem in the initialization stage. I’m currently testing the effect 
of distance between clusters in nano wire calculation. When the distance is 
small (size of unit cell is small), everything is initialized properly. When I 
increase the distance until the size of unit cell is as large as 70x70x30 in 
bohr, I met the following problem:

dstart -c -p    (14:31:23) running dstart in single mode
Segmentation fault
13.207u 0.136s 0:13.62 97.8%    0+0k 0+18312io 0pf+0w
error: command   /Users/wenhhu/wien2k14/dstartpara -c start.def   failed

Can anyone tell what is this error? And How can we solve it?

Best,
Wenhao
_______________________________________________
Wien mailing list
[email protected]
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/[email protected]/index.html


--
--------------------------------------------------------------------------
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300             FAX: +43-1-58801-165982
Email: [email protected]    WIEN2k: http://www.wien2k.at
WWW:   http://www.imc.tuwien.ac.at/staff/tc_group_e.php
--------------------------------------------------------------------------
_______________________________________________
Wien mailing list
[email protected]
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/[email protected]/index.html

Reply via email to