This looks fairly large.

I do NOT understand your statement of using "the same RKMAX" ???
PAW does not have RKMAX and their KMAX has NOTHING to do with ours.
What was your RKMAX and what are youre sphere sizes ???

k-mesh: not only the grid is important ! As far as I know, VASP usually uses a "huge" temperature broadening. What FERMI-method are you using ?

spin-polarization ??

Is the PAW done with VASP and a fairly new release (accurate PAW potentials ?)

On 01/29/2016 10:50 AM, Pavel Ondračka wrote:
Dear Wien2k mailing list,

I've been doing some calculation on a moderately large (around 100
atoms) amorphous-like SixTi1-xO2 cells produced by simulated annealing
MD in a PAW software. According to my colleague who did the final force
relaxation, the residual forces on atoms should be around 0.5
mRyd/Bohr. However when I calculate forces in Wien2k I see forces of
order of magnitude larger, eg. some as large as 30mRyd/Bohr.

This are exactly the same calculations: both using PBE, same k-grid,
same RKMAX (calculated from cutoff using the formula from UG) and I've
spent a lot of time checking the force convergence with respect to all
possible parameters.

We did some tests with small cells (eg. 10 atoms) and there we can get
a consistent results with max difference of forces around 10-20% which
I find reasonable. I'm actually quite clueless about it. I've been
suspecting user error at the beginning however I haven't found any so
far. My current theory is that in this large cases without symmetry
maybe the small differences between methods somehow sum up and hence
the big difference in final forces, however I would like to hear your
opinion in this matter.

Best regards
Pavel Ondračka
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


--

                                      P.Blaha
--------------------------------------------------------------------------
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300             FAX: +43-1-58801-165982
Email: bl...@theochem.tuwien.ac.at    WIEN2k: http://www.wien2k.at
WWW:   http://www.imc.tuwien.ac.at/staff/tc_group_e.php
--------------------------------------------------------------------------
_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to