Hi,

The volume is the one of the primitive cell, while the lattice
constant is for the conventional unit cell. For FCC, the conventional
cell is four times bigger than the primitive cell.

FT

On Wednesday 2016-12-14 13:25, Rajneesh Chaurasiya wrote:

Date: Wed, 14 Dec 2016 13:25:10
From: Rajneesh Chaurasiya <rajnano2...@gmail.com>
Reply-To: A Mailing list for WIEN2k users <wien@zeus.theochem.tuwien.ac.at>
To: Wien@zeus.theochem.tuwien.ac.at
Subject: Re: [Wien] volume optimization

Dear All,

My system is face centered cubic Fm-3m and .ps attached through this mail

thank you

On Tue, Dec 13, 2016 at 5:00 PM, Rajneesh Chaurasiya <rajnano2...@gmail.com>
wrote:
     Dear all.
I have optimised the cubic structure by calculating the total energy
with varying the lattice parameter size (%). In the optimised file,
data has been plotted between the total energy and volume of cell. i
found that the optimized lattice parameter is 8.19 angstrom and
corresponding volume of cell is 928.34 (a.u3). now if i change the
lattice parameter from angstrom to atomic unit and calculate the
volume then i found 3702 (a.u3) approx. so i could not find how the
conversion taken place. So can any one suggest what types of
conversion are happened in the background.   

--
Thanks & RegardsRajneesh Chaurasiya
Research Scholar
IIT Jodhpur, India
Mob. No. +91-9584499697
              +91-7610950803




--
Thanks & RegardsRajneesh Chaurasiya
Research Scholar
IIT Jodhpur, India
Mob. No. +91-9584499697
              +91-7610950803

_______________________________________________
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html

Reply via email to