With a good k-mesh the difference with TEMPS [1] & TETRA for an insulator will be minimal. For a metal there will be a little as the default is at room temperature. Perhaps 1/40 eV/atom, which is far less than functional errors.
[1] TEMP is not variationally rigorous, so may introduce small errors. They probably don't matter unless you do phonons or similar. -- Professor Laurence Marks Department of Materials Science and Engineering, Northwestern University www.numis.northwestern.edu "Research is to see what everybody else has seen, and to think what nobody else has thought" Albert Szent-Györgyi On Tue, Jul 26, 2022, 6:36 AM shamik chakrabarti <[email protected]> wrote: > Dear Wien2k users, > > I have a structure with a 2D Brillouin Zone. I have > obtained the optimized structure with TETRA while when calculating EnergyI > shifted to TEMP smearing. My query is whether we would get different > optimized structure with using TEMP or the effect of TEMP on structure is > minimal? > > Looking forward to your reply. > > with regards,. > > -- > Dr. Shamik Chakrabarti > Research Fellow > Department of Physics > Indian Institute of Technology Patna > Bihta-801103 > Patna > Bihar, India > _______________________________________________ > Wien mailing list > [email protected] > http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien > SEARCH the MAILING-LIST at: > http://www.mail-archive.com/[email protected]/index.html >
_______________________________________________ Wien mailing list [email protected] http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien SEARCH the MAILING-LIST at: http://www.mail-archive.com/[email protected]/index.html