On Tue, Nov 28, 2017 at 00:44:13 -0600, Bruno Wolff III <[email protected]> wrote:
I think the correct fix is to know if I reboot the router for testing something, I need to also restart wireguard to make sure it is sending data to the expected port. This isn't going to be an issue in normal operation.
I found a way to make it work more automatically. The reason the port was getting reassigned was because the original connection packet was being tracked and was conflicting with the source nat mapping even though in reallity the connection was the same. By putting in CT --notrack rules I was able to block that traking and without the conflict the port doesn't get remapped. I don't need tracking or the original connection for my firewall rules so this should be OK. On testing it seems to work as expected. Now when I reboot my router, my laptop reconnects and the wireguard tunnel works without having to restart it.