Hi Jason,
not the port. My external IP is dynamic. This is really standard for internet 
services in Germany offered to non-business users, or also business that prefer 
not the pay extra charges for the assignment of a static ip address. My IP 
address changes at least once a day (usually between 1 am and 2 am). Usually 
one uses a dyndns provider, and many routers support updating the ip address 
automatically. As I am running my external DNS with cloudflar, I am calling 
their API to update my external address.
Now afaik Wireguard resolves the domain name of the server just once to an IP 
address and not regularly or whenever the connection breaks down or has been 
idle for some time.
PersistentKeepAlive cannot address the issue, as the client is also not awake 
all the time in order to save energy. Looking at wg /? on windows I also don´t 
see any option that seems applicable..
Thanks, Joachim

-----Ursprüngliche Nachricht-----
Von: Jason A. Donenfeld <[email protected]> 
Gesendet: Sunday, 25 August 2019 20:36
An: Joachim Lindenberg <[email protected]>
Cc: Simon Rozman <[email protected]>; WireGuard mailing list 
<[email protected]>
Betreff: Re: Hyper-V 2019: unable to create wintun device: no interfaces found

On Sun, Aug 25, 2019 at 11:23 AM Joachim Lindenberg <[email protected]> 
wrote:
> my experiments were actually roughly three weeks ago with versions .18 and 
> .19, and that mail was somehow stuck..
> Just retried with .22, and the good news is that I was able to set up a 
> tunnel between a Hyper-V as a server and a windows client. The old error on 
> wintun is gone.

Good to hear.

> trick wireguard to work around the dynamic IP issue most Germans face. With 
> the Ubuntu vms I can ping the server from the client, and if it is 
> unreachable I am pulling down the interface and then up again.

Not sure I understand exactly. Is the goal to simply change/re-randomize your 
listen-port due to some weird quirks of your router's NAT table, in which case 
`wg set wg0 listen-port 0` will probably work better than down/up? Or is this 
actually a case where adding PersistentKeepalive=25 could fix things? Both of 
these options, anyhow, are available in the Windows client. wg.exe is installed 
into
system32 and works as expected.

_______________________________________________
WireGuard mailing list
[email protected]
https://lists.zx2c4.com/mailman/listinfo/wireguard