I hate to ask this question, but I'm at my wit's end with this one. I recently installed a new customer (2.4 GHz) with a clear LOS to my tower. The distance is less than a mile and I get -56 dBm of signal strength. I've run a spectrum analyzer and it's dead silent when the radio's off.. All sounds great! A real simple install, but the radio intermittently locks up, fails to associate and most recently, simply fails to work for more then 10 - 30 seconds at a time following a POR. I've replaced radio (Tranzeo SL2) and gone to the latest version of firmware. I even contacted Tranzeo Tech Support and follwed their recommendations for timing settings. The only difference between this client and all the others on my tower is that there is a power line in the LOS path. Has anyone else found this to be a problem? It's almost like an invisible concrete wall is between the AP and the site.
Thanks, Jim.... Jim Stout LTO Communications, LLC 15701 Henry Andrews Dr Pleasant Hill, MO 64080 (816) 305-1076 - Mobile (816) 497-0033 - Pager -- WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/