Uhm the ZS series is not designed for PoE application and has a clamp normally of 12v. You need the MJ8 series with the appropriate clamp level. The MJ8 series is designed for PoE applications. 48V version http://store.wisp-router.com/itemdesc.asp?ic=SP-POE-MJ8&eq=&Tp= 24V version http://store.wisp-router.com/itemdesc.asp?ic=SP-POE-MJ24&eq=&Tp=
Mj8 series info http://www.citel.fr/mj8-505-p-48-en.html http://www.citelprotection.com/POE.htm ZS series info http://www.citel.fr/zs-p-49-en.html Sorry.. / Eje -----Original Message----- From: wireless-boun...@wispa.org [mailto:wireless-boun...@wispa.org] On Behalf Of RickG Sent: Tuesday, July 07, 2009 10:39 PM To: WISPA General List Subject: [WISPA] ethernet surge protection I've got a very nice set of Citel ZS-CAT5/CL ethernet surge protectors. Unfortunately, either they dont like POE or I had them in the wrong direction because they killed a set of power supplies in about 10 minutes. They are marked with "input' and "output". Any ideas which way is the correct direction or does it not matter? -RickG ---------------------------------------------------------------------------- ---- WISPA Wants You! Join today! http://signup.wispa.org/ ---------------------------------------------------------------------------- ---- WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/ -------------------------------------------------------------------------------- WISPA Wants You! Join today! http://signup.wispa.org/ -------------------------------------------------------------------------------- WISPA Wireless List: wireless@wispa.org Subscribe/Unsubscribe: http://lists.wispa.org/mailman/listinfo/wireless Archives: http://lists.wispa.org/pipermail/wireless/