I have found that this is caused by adding the entries from a heat extraction
of a COM library as well as some extra-manual RegistryValue elements for the
interfaces under HKCR. Example causing the exception:
To fix it simply put in your component only what heat.exe generates. I
would put business-logic specific registry entries in another component and
fragment.
--
View this message in context:
http://windows-installer-xml-wix-toolset.687559.n2.nabble.com/Re-light-exe-error-LGHT0001-Item-has-already-been-added-Key-in-dictionary-tp7584833p7589433.html
Sent from the wix-devs mailing list archive at Nabble.com.
------------------------------------------------------------------------------