Thanks again for the help. I'll continue to scour MSDN for more
information. These errors will probably disappear since I'll be including
some default UI sequences with the -ext WixUIExtension.dll parameter
(terminology?). Thanks again!
On 12/21/06, Rob Mensching <[EMAIL PROTECTED]> wrote:
Because now that you have UI, the Windows Installer will call back to
your UI for things like FileInUse and random error handling. MSDN should
talk about this stuff more.
*From:* Levi Wilson [mailto:[EMAIL PROTECTED]
*Sent:* Thursday, December 21, 2006 13:32
*To:* Rob Mensching; wix-users@lists.sourceforge.net
*Subject:* Re: [WiX-users] ICE20 with WiX v3
Sorry about that. Have you much experience with adding custom dialogs? I
guess I just don't understand why adding a single dialog created all of
these ICE errors when the UI-less install was perfectly fine.
On 12/21/06, *Rob Mensching* <[EMAIL PROTECTED]> wrote:
Please keep wix-users on the line so everyone sees the replies.
Yes, MSDN provides explanations about all of the ICEs and common ways to
fix them.
*From:* Levi Wilson [mailto:[EMAIL PROTECTED]
*Sent:* Thursday, December 21, 2006 13:19
*To:* Rob Mensching
*Subject:* Re: [WiX-users] ICE20 with WiX v3
Thanks for the quick response. I'm very new to Windows Installer, would
the best place to find out about these ICExxx errors be MSDN? I guess I'm
just not sure what it is expecting. I'll continue to look into these
errors. Thanks!
On 12/21/06, *Rob Mensching* <[EMAIL PROTECTED]> wrote:
The difference you're seeing is that WiX v2 did not run validation and WiX
v3 does. Those are errors in your WiX v2 package, you just didn't know it
before. <smile/>
*From:* [EMAIL PROTECTED] [mailto:
[EMAIL PROTECTED] *On Behalf Of *Levi Wilson
*Sent:* Thursday, December 21, 2006 12:54
*To:* wix-users@lists.sourceforge.net
*Subject:* [WiX-users] ICE20 with WiX v3
I receive the following errors when trying to follow along with part 8 of
the tutorial when linking with version 3 (all ICE20s BTW):
- Standard Dialog: 'FilesInUse' not found in Dialog table
- ErrorDialog Property not specified in Property table
- Exit dialog/action not found in AdminUISequence (and one about
InstallUISequence
- etc.
Can anyone offer me any insight or point me to a website that indicates
some of the differences between version 2 and 3 of the linker and why I keep
running into ICExxx errors? Any help would be greatly appreciated, thanks!
Levi
-------------------------------------------------------------------------
Take Surveys. Earn Cash. Influence the Future of IT
Join SourceForge.net's Techsay panel and you'll get the chance to share your
opinions on IT & business topics through brief surveys - and earn cash
http://www.techsay.com/default.php?page=join.php&p=sourceforge&CID=DEVDEV
_______________________________________________
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users