Ignore this. I figured out:
<Package InstallerVersion='200' ...> should be supplied.
From: Sunghwa Jin
Sent: Tuesday, June 19, 2007 3:17 PM
To: 'WiX-users@lists.sourceforge.net'
Subject: ICE66: Complete functionality of the MsiAssembly table is only
available with Windows Installer version 1.5. Your schema is 100.
Hi all,
I'm getting this error after I switch to WiX v3 when running Light.exe. Can
someone give me any clue about this warning? How can I solve this issue? Light
version is 3.0.2712.0:
warning LGHT1076 : ICE66: Complete functionality of the MsiAssembly table is
only available with Windows Installer version 1.5. Your schema is 100.
Thanks,
Sunghwa
-------------------------------------------------------------------------
This SF.net email is sponsored by DB2 Express
Download DB2 Express C - the FREE version of DB2 express and take
control of your XML. No limits. Just data. Click to get it now.
http://sourceforge.net/powerbar/db2/
_______________________________________________
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users