Brett Kapilik wrote:
I have seen this several times as well. It seems to have something to do with using an ALLCAPS directory id (COMBINEDPRODUCTFOLDER). Try putting at least one lower case letter in and it will work. I do not know why this happens. COuld it have something to do with the ALLCAPS directory ID being treated as a public property?

That's actually a requirement, per the MSI SDK doc on the Feature table. MSI has to pass the user's choice from the UI sequence to the execute sequence and a public property enables that.

--
sig://boB