Hi, I'm including the msvc9 crt merge module and its related policy merge module, after doing so I am turning up the following errors:
main.wxs(323,0): Warning LGHT1055: The InstallExecuteSequence table contains an action 'SxsInstallCA' which cannot be merged from the merge module 'policy_9_0_Microsoft_VC90_CRT_x86.msm'. This action is likely colliding with an action in the database that is being created. The colliding action may have been authored in the database or merged in from another merge module. If this is a standard action, it is likely colliding due to a difference in the condition for the action in the database and merge module. If this is a custom action, it should only be declared in the database or one merge module. main.wxs(323,0): Warning LGHT1055: The InstallExecuteSequence table contains an action 'SxsUninstallCA' which cannot be merged from the merge module 'policy_9_0_Microsoft_VC90_CRT_x86.msm'. This action is likely colliding with an action in the database that is being created. The colliding action may have been authored in the database or merged in from another merge module. If this is a standard action, it is likely colliding due to a difference in the condition for the action in the database and merge module. If this is a custom action, it should only be declared in the database or one merge module. light.exe(0,0): Warning LGHT1076: ICE03: String overflow (greater than length permitted in column); Table: AdminExecuteSequence, Column: Action, Key(s): WindowsFolder.21022.08.Microsoft_VC90_CRT_x86.RTM.0138F525_6C8A_333F_A105_14AE030B9A54 --- lots of ICE03 errors --- light.exe(0,0): Warning LGHT1076: ICE82: This action SystemFolder.21022.08.Microsoft_VC90_CRT_x86.RTM.0138F525_6C8A_333F_A105_14AE030B9A54 has duplicate sequence number 2 in the table InstallUISequence light.exe(0,0): Warning LGHT1076: ICE82: This action SystemFolder.21022.08.Microsoft_VC90_CRT_x86.RTM.0138F525_6C8A_333F_A105_14AE030B9A54 has duplicate sequence number 2 in the table AdminUISequence light.exe(0,0): Warning LGHT1076: ICE82: This action SystemFolder.21022.08.Microsoft_VC90_CRT_x86.RTM.0138F525_6C8A_333F_A105_14AE030B9A54 has duplicate sequence number 2 in the table AdvtExecuteSequence light.exe(0,0): Warning LGHT1076: ICE83: The keypath for Global Win32 SXS Assembly (Component_=uplevel.21022.08.policy_9_0_Microsoft_VC90_CRT_x86.RTM.52105B6B_A3EF_3A90_882A_947B287C203A) SHOULD NOT be it's manifest file for assemblies other than Win32 Policy assemblies Are any of these things which I should worry about or or they not critical errors? -- View this message in context: http://www.nabble.com/merging-vc9-modules-tf4889617.html#a13996014 Sent from the wix-users mailing list archive at Nabble.com. ------------------------------------------------------------------------- SF.Net email is sponsored by: The Future of Linux Business White Paper from Novell. From the desktop to the data center, Linux is going mainstream. Let it simplify your IT future. http://altfarm.mediaplex.com/ad/ck/8857-50307-18918-4 _______________________________________________ WiX-users mailing list WiX-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wix-users