I learned a few years back not to change my upgrade code, unfortunately a
little too late. The good news is that I only changed it once. My current
WiX source is:
<Product Id="A390115B-BF30-4481-8F46-9615FEE3C5C5" Name="MyProduct"
Language="1033" Version="$(var.Version)" Manufacturer="MyCompany"
UpgradeCode="9B672C80-9A35-4EA5-9A9B-7D7E3626E912">
...
<Upgrade Id="9B672C80-9A35-4EA5-9A9B-7D7E3626E912">
<UpgradeVersion Minimum="3.0.0.1"
IncludeMinimum="yes"
Maximum="$(var.Version)"
IncludeMaximum="no"
Language="1033"
Property="UPGRADE_OLD_VERSION" />
<UpgradeVersion Minimum="$(var.Version)"
IncludeMinimum="no"
OnlyDetect="yes"
Language="1033"
Property="NEWPRODUCTFOUND" />
</Upgrade>
<Upgrade Id="A2787551-7D36-4B1B-9FC7-58C4D483114C">
<UpgradeVersion Minimum="1.0.0.0"
IncludeMinimum="yes"
Maximum="3.0.0.0"
IncludeMaximum="no"
Language="1033"
Property="UPGRADE_ANCIENT_VERSION" />
</Upgrade>
And what I'm seeing is that version 3.0.0.1 and later is being upgraded
properly, but prior versions (those having UpgradeCode
9B672C80-9A35-4EA5-9A9B-7D7E3626E912) are not being uninstalled and are left
on the machine.
Can anybody spot what I'm doing wrong here?
Thanks,
-Chris
-------------------------------------------------------------------------