Hello,

In the MergeModule I am developing with WiX 2, I need Substitution entries in 
order to use some properties from the base MSI; however I do not need 
Configuration entries because I do not need the module to be configured at 
merge time.

The resulting MSM contains a ModuleSubstitution table but no 
ModuleConfiguration table.

When I merge the module into the base MSI using Orca, Orca fails to search for 
orphaned rows (because the Moduleconfiguration table is missing) This error is 
only detected when I run the command-line version of Orca and have a log file 
be written, but as a consequence Orca does not connect the module components to 
a feature of the base MSI.

When I create an (empty) ModuleConfiguration table in the merge module, 
everything works fine.

So as a workaround, I add a dummy <Configuration> element to my Module.

Shouldn't WiX create a ModuleConfiguration table whenever there are entries in 
the ModuleSubstitution table?

Best regards,

Matthias

------------------------------------------------------------------------------