After rebuilding WIX 3.0.5419.0 locally without errors I am unable to
reference the WixUIExtension.dll, no source modifications were made.
When attempting to select the rebuilt file Visual Studio errors with "A
reference to C:\Wix3.0\Build\Debug\x86\ WixUIExtension.dll could not be
added.  Please make sure that the file is accessible, and that it is a
valid reference."

I installed the Wix3.msi on this machine for use with VS 2008

I downloaded WIX 3.0 sources from Codeplex from label 

I verified delay signing was used with ILDasm and that CAS is properly
configured for WIX (even turned off CAS to test).

C:\WIX30\src\ext\UIExtension>sn -Vl

Microsoft (R) .NET Framework Strong Name Utility Version 3.5.30729.1

Copyright (c) Microsoft Corporation.  All rights reserved.

Assembly/Strong Name                  Users

===========================================

*,36e4ce08b8ecfb17                    All users

WixUIExtension,36E4CE08B8ECFB17       All users

I'm an admin on the machine and have the necessary access.  To test, I
moved the dll to a folder with a working reference and have the same
issue.  

------------------------------------------------------------------------
----
This message and any included attachments are from Siemens Medical
Solutions 
and are intended only for the addressee(s). 
The information contained herein may include trade secrets or privileged
or 
otherwise confidential information. Unauthorized review, forwarding,
printing, 
copying, distributing, or using such information is strictly prohibited
and may 
be unlawful. If you received this message in error, or have reason to
believe 
you are not authorized to receive it, please promptly delete this
message and 
notify the sender by e-mail with a copy to
central.securityoff...@siemens.com 

Thank you
------------------------------------------------------------------------
----
This message and any included attachments are from Siemens Medical
Solutions 
and are intended only for the addressee(s). 
The information contained herein may include trade secrets or privileged
or 
otherwise confidential information. Unauthorized review, forwarding,
printing, 
copying, distributing, or using such information is strictly prohibited
and may 
be unlawful. If you received this message in error, or have reason to
believe 
you are not authorized to receive it, please promptly delete this
message and 
notify the sender by e-mail with a copy to
central.securityoff...@siemens.com 

Thank you

----------------------------------------------------------------------------
This message and any included attachments are from Siemens Medical Solutions 
and are intended only for the addressee(s). 
The information contained herein may include trade secrets or privileged or 
otherwise confidential information. Unauthorized review, forwarding, printing, 
copying, distributing, or using such information is strictly prohibited and may 
be unlawful. If you received this message in error, or have reason to believe 
you are not authorized to receive it, please promptly delete this message and 
notify the sender by e-mail with a copy to central.securityoff...@siemens.com 

Thank you
------------------------------------------------------------------------------
This SF.net email is sponsored by Sprint
What will you do first with EVO, the first 4G phone?
Visit sprint.com/first -- http://p.sf.net/sfu/sprint-com-first
_______________________________________________
WiX-users mailing list
WiX-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wix-users

Reply via email to