On Sat, May 7, 2011 at 1:46 PM, Christopher Painter <chr...@deploymentengineering.com> wrote: > I'm not an IA expert, but what you just described sounds like the PackageCode > not the UpgradeCode or the ProductCode.
You are indeed 100% correct Sir! There was a project properties or something in the IDE, and that was where the UpgradeCode was stuck. Now my log file contains: MSI (s) (5C:28) [14:12:14:602]: Note: 1: 2205 2: 3: ActionText Action 14:12:14: RemoveExistingProducts. Removing applications Action start 14:12:14: RemoveExistingProducts. RemoveExistingProducts: Application: {1DDFD196-41B9-4896-AB46-3BD7E23858A0}, Command line: UPGRADINGPRODUCTCODE={1CAE062D-4682-4A0E-B92E-CD581A2F17BF} CLIENTUILEVEL=0 REMOVE=ALL Which provides me with a sense of great relief! Thanks again Christopher for pushing my all-thumbs approach through. -- Rune ------------------------------------------------------------------------------ WhatsUp Gold - Download Free Network Management Software The most intuitive, comprehensive, and cost-effective network management toolset available today. Delivers lowest initial acquisition cost and overall TCO of any competing solution. http://p.sf.net/sfu/whatsupgold-sd _______________________________________________ WiX-users mailing list WiX-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wix-users