Hi Peter,
I only find one reference to the missing components:
MSI (s) (18:04) [11:55:50:138]: Executing op:
ComponentRegister(ComponentId={FEA74860-747D-4065-ABB8-7921CEE2BAF3},KeyPath=C:\cmsoft\60970\10021.Ver,State=3,,Disk=1,SharedDllRefCount=0,BinaryType=0)
MSI (s) (18:04) [11:55:50:140]: Executing op:
ComponentRegister(ComponentId={027A9F27-B80E-4914-9C89-073012511CF3},KeyPath=C:\cmsoft\60970\SurvApp
- Copy.INI,State=3,,Disk=1,SharedDllRefCount=0,BinaryType=0)
The first is a missing one, the second, seemingly identical in character, is
one which survives.
On the other hand,
MSI (s) (18:04) [11:55:51:036]: Executing op:
FileCopy(SourceName=qfix30zb.ini|SurvApp -
Copy.INI,SourceCabKey=Fc3cde52e85bc4,DestName=SurvApp -
Copy.INI,Attributes=4608,FileSize=131,PerTick=32768,,VerifyMedia=1,,,,,CheckCRC=0,,,InstallMode=58982400,HashOptions=0,HashPart1=-482575987,HashPart2=-268032772,HashPart3=916218091,HashPart4=1544468535,,)
MSI (s) (18:04) [11:55:51:037]: File: C:\cmsoft\60970\SurvApp - Copy.INI;
To be installed; Won't patch; No existing file
a reference of this sort exists for each of the files that survive.
Keith Douglas
Statistics Canada | 170 Tunney's Pasture Driveway, Ottawa ON K1A 0T6
Statistique Canada | 170, promenade Tunney's Pasture, Ottawa ON K1A 0T6
[email protected]
Telephone | Téléphone 613-951-4405
Facsimile | Télécopieur 613-951-1966
Government of Canada | Gouvernement du Canada
-----Original Message-----
From: Peter Shirtcliffe [mailto:[email protected]]
Sent: April-17-12 4:41 AM
To: General discussion for Windows Installer XML toolset.
Subject: Re: [WiX-users] MSP question
What does a verbose log say about the disappearing components ?
-----Original Message-----
From: [email protected] [mailto:[email protected]]
Sent: 16 April 2012 17:59
To: [email protected]
Subject: [WiX-users] MSP question
Hi everyone,
I'm using pyro to attempt to generate an .MSP file to use. In its .wxs, I have
(for now) a single componentref which seems to work out ok, i.e. the patch
successfully installs the additional file referenced by the new component.
However, for some reason, the .MSP also as part of its operation removes some
of the original files: not all of them and with seemingly no pattern. Each
component "lost" a few files. All I can see is that the ones which did not
survive the upgrade are ones flagged with a 512 attribute in the File
Attributes column; the ones which made it are 4608 (i.e. 512+4096), which as
far as I can tell is correct in this context. This prompts the question: what
would create any difference between some files and others? My .wxs for the full
MSI seems to contain all the files referenced properly. All files are
keypath="yes" for what that's worth ...
For example, under one directory:
<Component Id="F38afa489ded74"
Guid="fea74860-747d-4065-abb8-7921cee2baf3">
<File Id="F38afa489ded74" Source="c:\cmsoft\60970\10021.Ver"
KeyPath="yes" />
</Component>
<Component Id="Fc3cde52e85bc4"
Guid="027a9f27-b80e-4914-9c89-073012511cf3">
<File Id="Fc3cde52e85bc4" Source="c:\cmsoft\60970\SurvApp - Copy.INI"
KeyPath="yes" />
</Component>
<Component Id="F55ff3f88e49d4"
Guid="a38fc47d-8d1b-4a0e-91da-2b9e9becac10">
<File Id="F55ff3f88e49d4" Source="c:\cmsoft\60970\SURVAPP.exe"
KeyPath="yes" Checksum="yes" />
</Component>
<Component Id="F638bbbdf0bfd4"
Guid="90e0f205-be97-419b-88f8-41a5bcc94be8">
<File Id="F638bbbdf0bfd4" Source="c:\cmsoft\60970\SurvApp.INI"
KeyPath="yes" />
</Component>
<Component Id="F647d809bd1b64"
Guid="86717730-1a04-4bb5-8dfb-83b844da4167">
<File Id="F647d809bd1b64" Source="c:\cmsoft\60970\Vsconfig.mdb"
KeyPath="yes" />
</Component>
Only fileid="Fc3cde52e85bc4" made it.
Even the number of "surviving" files is variable (it isn't as if it was only
1 or only the first few, etc.)
The strange IDs, BTW, come from me generating this with an installerbuilder
application I am working on to help automate installer package making for us.
Keith Douglas
Statistics Canada | 170 Tunney's Pasture Driveway, Ottawa ON K1A 0T6
Statistique Canada | 170, promenade Tunney's Pasture, Ottawa ON K1A 0T6
[email protected] Telephone | Téléphone 613-951-4405 Facsimile |
Télécopieur 613-951-1966 Government of Canada | Gouvernement du Canada
-----------------------------------------------------------------------------
-
For Developers, A Lot Can Happen In A Second.
Boundary is the first to Know...and Tell You.
Monitor Your Applications in Ultra-Fine Resolution. Try it FREE!
http://p.sf.net/sfu/Boundary-d2dvs2
_______________________________________________
WiX-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wix-users
SDL PLC confidential, all rights reserved.
If you are not the intended recipient of this mail SDL requests and requires
that you delete it without acting upon or copying any of its contents, and we
further request that you advise us.
SDL PLC is a public limited company registered in England and Wales.
Registered number: 02675207.
Registered address: Globe House, Clivemont Road, Maidenhead, Berkshire SL6 7DY,
UK.
------------------------------------------------------------------------------
Better than sec? Nothing is better than sec when it comes to monitoring Big
Data applications. Try Boundary one-second resolution app monitoring today.
Free.
http://p.sf.net/sfu/Boundary-dev2dev
_______________________________________________
WiX-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wix-users
------------------------------------------------------------------------------
Better than sec? Nothing is better than sec when it comes to
monitoring Big Data applications. Try Boundary one-second
resolution app monitoring today. Free.
http://p.sf.net/sfu/Boundary-dev2dev
_______________________________________________
WiX-users mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wix-users