Hi, I am looking for some help. We have a Continuous Integration Build that is running a Wix project that I have created. It runs fine locally but when you run the build job it keeps failing. The error that I am getting is:
Task "HeatDirectory" Command: C:\Program Files (x86)\WiX Toolset v3.7\bin\Heat.exe dir "C:\Builds\<SOMEPATH>\obj\Debug\Package\PackageTmp" -cg WebProject_Project -dr INSTALLLOCATION -scom -sreg -srd -var var.BasePath -gg -sfrag -out WebProject.wxs Could not load file or assembly 'file:///C:\Program Files (x86)\WiX Toolset v3.7\bin\Heat.exe' or one of its dependencies. An attempt was made to load a program with an incorrect format. at System.Reflection.RuntimeAssembly._nLoad(AssemblyName fileName, String codeBase, Evidence assemblySecurity, RuntimeAssembly locationHint, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean throwOnFileNotFound, Boolean forIntrospection, Boolean suppressSecurityChecks) at System.Reflection.RuntimeAssembly.InternalLoadAssemblyName(AssemblyName assemblyRef, Evidence assemblySecurity, RuntimeAssembly reqAssembly, StackCrawlMark& stackMark, IntPtr pPrivHostBinder, Boolean throwOnFileNotFound, Boolean forIntrospection, Boolean suppressSecurityChecks) at System.Reflection.RuntimeAssembly.InternalLoadAssemblyName(AssemblyName assemblyRef, Evidence assemblySecurity, RuntimeAssembly reqAssembly, StackCrawlMark& stackMark, Boolean throwOnFileNotFound, Boolean forIntrospection, Boolean suppressSecurityChecks) at System.Reflection.RuntimeAssembly.InternalLoadFrom(String assemblyFile, Evidence securityEvidence, Byte[] hashValue, AssemblyHashAlgorithm hashAlgorithm, Boolean forIntrospection, Boolean suppressSecurityChecks, StackCrawlMark& stackMark) at System.Reflection.Assembly.LoadFrom(String assemblyFile) at Microsoft.Tools.WindowsInstallerXml.Build.Tasks.WixToolTask.ExecuteToolThread(Object parameters) I can't see anything wrong with the set up and I have installed wix to the server. I have modified the BeforeBuild which is: <Target Name="BeforeBuild"> <MSBuild Projects="%(ProjectReference.FullPath)" Targets="Package" Properties="Configuration=$(Configuration);Platform=AnyCPU" Condition="'%(ProjectReference.PackageThisProject)'=='True'" /> <PropertyGroup> <DefineConstants>BasePath=%(ProjectReference.RootDir)%(ProjectReference.Directory)obj\$(Configuration)\Package\PackageTmp\;</DefineConstants> <LinkerBaseInputPaths>%(ProjectReference.RootDir)%(ProjectReference.Directory)obj\$(Configuration)\Package\PackageTmp\</LinkerBaseInputPaths> </PropertyGroup> <HeatDirectory OutputFile="%(ProjectReference.Filename).wxs" Directory="%(ProjectReference.RootDir)%(ProjectReference.Directory)obj\$(Configuration)\Package\PackageTmp" DirectoryRefId="INSTALLLOCATION" ComponentGroupName="%(ProjectReference.Filename)_Project" SuppressCom="true" SuppressFragments="true" SuppressRegistry="true" SuppressRootDirectory="true" AutoGenerateGuids="false" GenerateGuidsNow="true" ToolPath="$(WixToolPath)" PreprocessorVariable="var.BasePath" Condition="'%(ProjectReference.PackageThisProject)'=='True'" /> </Target> Also I am using Wix 3.7. Any help is appreciated. Brian ------------------------------------------------------------------------------ Symantec Endpoint Protection 12 positioned as A LEADER in The Forrester Wave(TM): Endpoint Security, Q1 2013 and "remains a good choice" in the endpoint security space. For insight on selecting the right partner to tackle endpoint security challenges, access the full report. http://p.sf.net/sfu/symantec-dev2dev _______________________________________________ WiX-users mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/wix-users