Or that you have the MSI open in Orca while trying to install it :) -- Nicolás
2014-10-13 12:16 GMT-03:00 Phil Wilson <phildgwil...@gmail.com>: > Error 1619 is "This installation package could not be opened. Verify > that the package exists and is accessible, or contact the application > vendor to verify that this is a valid Windows Installer package." > Something about the context of the install or the security (or > sometimes when the file is already open) means that Windows can't get > access to the MSI file. > --------------- > Phil Wilson > > > On Sun, Oct 12, 2014 at 11:15 PM, Yankulin, Leonid > <leonid.yanku...@mckesson.com> wrote: >> Hello, >> I am trying to run silent installation of my MSI (WiX 3.8; VS2013) with /qn >> parameter. When the MSI is stored locally on computer I am getting a pretty >> long log with no errors, which ends with "nothing". No files installed, no >> IIS virtual directories created, no SQL scripts ran. I am suspecting it is >> somehow relates to execution sequence, but I do not know where to start. We >> have customized UI that makes use of custom actions. However, all >> installations are implemented using components and WiX iis and sql elements. >> When I am trying to install the file from remote location I am getting the >> following log only: >> ----- >> === Verbose logging started: 13/10/2014 08:41:26 Build type: SHIP UNICODE >> 5.00.7601.00 Calling process: C:\Windows\system32\msiexec.exe === >> MSI (c) (C4:B4) [08:41:26:585]: Resetting cached policy values >> MSI (c) (C4:B4) [08:41:26:585]: Machine policy value 'Debug' is 0 >> MSI (c) (C4:B4) [08:41:26:585]: ******* RunEngine: >> ******* Product: >> \\migspicard\builds\Picard_Test\Picard_Test_101314.01 >> ******* Action: >> ******* CommandLine: ********** >> MSI (c) (C4:B4) [08:41:26:586]: Client-side and UI is none or basic: Running >> entire install on the server. >> MSI (c) (C4:B4) [08:41:26:586]: Grabbed execution mutex. >> MSI (c) (C4:B4) [08:41:26:667]: Cloaking enabled. >> MSI (c) (C4:B4) [08:41:26:667]: Attempting to enable all disabled privileges >> before calling Install on Server >> MSI (c) (C4:B4) [08:41:26:670]: Incrementing counter to disable shutdown. >> Counter after increment: 0 >> MSI (s) (B4:D8) [08:41:26:678]: Running installation inside multi-package >> transaction \\migspicard\builds\Picard_Test\Picard_Test_101314.01 >> MSI (s) (B4:D8) [08:41:26:678]: Grabbed execution mutex. >> MSI (s) (B4:68) [08:41:26:679]: Resetting cached policy values >> MSI (s) (B4:68) [08:41:26:679]: Machine policy value 'Debug' is 0 >> MSI (s) (B4:68) [08:41:26:679]: ******* RunEngine: >> ******* Product: >> \\migspicard\builds\Picard_Test\Picard_Test_101314.01 >> ******* Action: >> ******* CommandLine: ********** >> MSI (s) (B4:68) [08:41:26:989]: Note: 1: 2203 2: >> \\migspicard\builds\Picard_Test\Picard_Test_101314.01 3: -2147287035 >> MSI (s) (B4:68) [08:41:26:990]: MainEngineThread is returning 1619 >> MSI (s) (B4:D8) [08:41:26:991]: User policy value 'DisableRollback' is 0 >> MSI (s) (B4:D8) [08:41:26:991]: Machine policy value 'DisableRollback' is 0 >> MSI (s) (B4:D8) [08:41:26:991]: Incrementing counter to disable shutdown. >> Counter after increment: 0 >> MSI (s) (B4:D8) [08:41:26:991]: Note: 1: 1402 2: >> HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Installer\Rollback\Scripts >> 3: 2 >> MSI (s) (B4:D8) [08:41:26:992]: Note: 1: 1402 2: >> HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Installer\Rollback\Scripts >> 3: 2 >> MSI (s) (B4:D8) [08:41:26:992]: Note: 1: 1402 2: >> HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Installer\InProgress >> 3: 2 >> MSI (s) (B4:D8) [08:41:26:992]: Note: 1: 1402 2: >> HKEY_LOCAL_MACHINE\Software\Microsoft\Windows\CurrentVersion\Installer\InProgress >> 3: 2 >> MSI (s) (B4:D8) [08:41:26:992]: Decrementing counter to disable shutdown. If >> counter >= 0, shutdown will be denied. Counter after decrement: -1 >> MSI (s) (B4:D8) [08:41:26:992]: Restoring environment variables >> MSI (c) (C4:B4) [08:41:26:994]: Decrementing counter to disable shutdown. If >> counter >= 0, shutdown will be denied. Counter after decrement: -1 >> MSI (c) (C4:B4) [08:41:26:995]: MainEngineThread is returning 1619 >> === Verbose logging stopped: 13/10/2014 08:41:26 === >> ----- >> >> Please, advise about what additional information is required to figure why >> the local silent setup isn't working AND why a slient setup from remote >> location behaves weird. >> >> Thank you, >> Leonid Yankulin >> Email: leonid.yanku...@mckesson.com<mailto:leonid.yanku...@mckesson.com> >> ------------------------------------------------------------------------------ Meet PCI DSS 3.0 Compliance Requirements with EventLog Analyzer Achieve PCI DSS 3.0 Compliant Status with Out-of-the-box PCI DSS Reports Are you Audit-Ready for PCI DSS 3.0 Compliance? Download White paper Comply to PCI DSS 3.0 Requirement 10 and 11.5 with EventLog Analyzer http://p.sf.net/sfu/Zoho _______________________________________________ WiX-users mailing list WiX-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wix-users