I'm working on rolling out Autodesk Revit Structure 2008, but I think this will 
apply 
to all of the current Autodesk Autocad and Revit versions.  It seems Autodesk 
is 
using a different install program now.  I think they used to use Installshield? 
Maybe this new thing is their own invention.

The install is a two step process, like always.  First create a deployment on 
your 
network, then run a setup program on each workstation.  The setup program is a 
front 
end for various msi files that do the actual installation.  It checks for 
prerequisites and sets some parameters.

In my testing with WPKG I could not get a successful installation. WPKG starts 
the 
"setup.exe", and the setup eventually runs the msi to install the program, but 
then 
WPKG looks for and fails to find the uninstall string and reports that the 
installation failed.  Meanwhile setup is still running (I think) apparently 
calling 
other programs to do some final configuration, which may be when the uninstall 
program is actually configured.  In any event, it seems like a timing problem, 
where 
WPKG doesn't wait long enough before doing the "check", or more likely, setup 
indicates that it is finished when it really isn't.

I've kind of worked around it, but it is ugly.  Does anyone have any experience 
with 
this or any insight?

Sequence of events in the log:

WpkgService - Set script security context: successfuly done.
WpkgService - Network resource: successfuly connected
WSH - User notification suppressed.
WSH - Installing Revit Structure 2008...

MSI installer - Product: Revit Structure 2008 -- Installation operation 
completed 
successfully.

WSH - User notification suppressed.
WSH - There were the following errors:
        Package name: Revit Structure 2008
        Could not install Revit Structure 2008.
        Failed checking after installation.

WpkgService - Script execution: successfuly done
WpkgService - Network resource: successfuly disconnected

MSI installer - Product: Revit Structure 2008 -- Installation operation 
completed 
successfully.

MSI installer - Failed to connect to server. Error: 0x800401F0


I know what you are thinking (there is something wrong with the "check").  But 
if I 
restart the computer after this, then it finds the uninstall string and updates 
the 
local wpkg.xml file to include the Revit program without running the install 
again.

Thanks,
Mark


-------------------------------------------------------------------------
This SF.net email is sponsored by DB2 Express
Download DB2 Express C - the FREE version of DB2 express and take
control of your XML. No limits. Just data. Click to get it now.
http://sourceforge.net/powerbar/db2/
_______________________________________________
wpkg-users mailing list
wpkg-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wpkg-users

Reply via email to