On 29/10/2014 15:28, Joe Taylor wrote:
Hi Bobby,
We know there are problems with CAT control of the TS-570, and your
problem was already reported. Most of the rig-control issues are being
handled by Bill, G4WJS. He is working on a solution, and we hope that
will be included in the next candidate release.
I have tried to contact Bobby off list but his email address doesn't work.
-- 73, Joe, K1JT
73
Bill
G4WJS.
On 10/29/2014 10:41 AM, Bobby Chandler wrote:
Hi Joe,
Is there a way to set the polling to 0 (zero) in V1.4. It is causing me
problems with the TS570 and I had the same problem
in previous versions if set to anything other than 0. I get an error message
and have to go into setup and re-initialize the
radio to continue when it happens. I don’t try the dual mode with the new beta
version.
Thanks and 73,
Bobby
[email protected]
[email protected]
---
This email is free from viruses and malware because avast! Antivirus protection
is active.
http://www.avast.com
------------------------------------------------------------------------------
_______________________________________________
wsjt-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wsjt-devel
--- Begin Message ---
This is the mail system at host mail.classdesign.com.
I'm sorry to have to inform you that your message could not
be delivered to one or more recipients. It's attached below.
For further assistance, please send mail to postmaster.
If you do so, please include this problem report. You can
delete your own text from the attached returned message.
The mail system
<[email protected]>: host gateway-f2.isp.att.net[207.115.11.16] refused to
talk to me: 550-62.49.44.173 blocked by ldap:ou=rblmx,dc=att,dc=net 550
Error - Blocked for abuse. See http://att.net/blocks
Reporting-MTA: dns; mail.classdesign.com
X-Postfix-Queue-ID: 653732D381A8
X-Postfix-Sender: rfc822; [email protected]
Arrival-Date: Tue, 7 Oct 2014 12:35:54 +0100 (BST)
Final-Recipient: rfc822; [email protected]
Original-Recipient: rfc822;[email protected]
Action: failed
Status: 4.0.0
Remote-MTA: dns; gateway-f2.isp.att.net
Diagnostic-Code: smtp; 550-62.49.44.173 blocked by ldap:ou=rblmx,dc=att,dc=net
550 Error - Blocked for abuse. See http://att.net/blocks
--- Begin Message ---
On 07/10/2014 12:24, 'Bobby Chandler' [email protected] [wsjtgroup]
wrote:
Hi Bobby,
Is there a plan to allow setting polling to 0? Polling is causing me
problems with the Kenwood TS570 and I have tried 1s to 99s. It
appears that when the radio is polled, CAT get confused and I have to
do a reset or a re(TEST) of the radio setup. It is worse when using
dual mode.
I am aware there is an issue with CAT communication using the TS-570(D).
I believe this is due to the CAT protocol handling on that rig being
fragile. I need to look at the underlying Hamlib library we use for
direct CAT control which has some options for slowing down the exchanges
with the radio both at the individual character level and between
message exchanges.
As for not having polling, this is not an option when using split
operation as we must know that the radio is responding correctly to the
commands we issue to it. CAT protocols are two way and if there is
defect with a particular rig we will sort it out. There is no reason why
two way CAT should not work, that is how it is designed to be used and
does so with many other rig control applications. At the moment I am
dealing with several other CAT issues. We expected this with the large
number of changes in the v1.4 version related to rig control.
Rest assured that your issue is not being ignored and I hope to dedicate
some time to it very soon.
Bobby/N4AU
[email protected]
[email protected]
73
Bill
G4WJS.
--- End Message ---
--- End Message ---
------------------------------------------------------------------------------
_______________________________________________
wsjt-devel mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/wsjt-devel