I'm hesitant to send this because I'm not sure if it's a bug or just isolated 
to me; I haven't been able to find anyone else with a similar experience.  
Please forgive me if it is not appropriate.  

I just compiled 1.7.0 devel r6418 and I am running Windows 10 Home 64 bit and 
using HRD 6.3.0.466 for CAT Control.  

I'm getting a "Rig Control Error" on startup.  More details as follows:

I usually use "Fake it" for the "Split" setting because that seems to work best 
with my Elecraft K3.  This is because if I use "rig" instead, the K3 hops in 
and out of "Split" mode randomly.  If I select "none" the power delivery is not 
smooth, especially close to the edges of the passband (which you all know :) ). 
 This worked quite well until the recent build where "Fake it" now throws the 
K3 into "split" mode when I start WSJT-X which then causes a "Rig Control 
Error" stating "Emulated split mode requires rig to be in simplex mode" which 
has never happened before.  Usually when "fake it" is selected, the rig remains 
in simplex mode and there are no issues.  

Anyone else getting this?  I didn't have this issue prior to r6418 and it isn't 
happening with 1.6, either.  

Like I said, not sure if this is really a "bug" yet but figured I'd put it out 
there just the same.  

Thanks for all the work being done on this.  

73,

Jim S. 
N2ADV
------------------------------------------------------------------------------
Site24x7 APM Insight: Get Deep Visibility into Application Performance
APM + Mobile APM + RUM: Monitor 3 App instances at just $35/Month
Monitor end-to-end web transactions and take corrective actions now
Troubleshoot faster and improve end-user experience. Signup Now!
http://pubads.g.doubleclick.net/gampad/clk?id=267308311&iu=/4140
_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel

Reply via email to