On 29/05/2016 16:36, [email protected] wrote:
> I did change the setting from HRD option to just IC7000. The WSJT-X 
> Started to decode right away. I had many stations worked. Yesterday 
> afternoon, the program give me a message: Hamlib collision while 
> trying to get the vfo.

HI Luis,

that error message is not quite right. When WSJT-X pops up a message box 
you can capture the exact message text by hitting CTRL+C and pasting 
into an email or text editor. For the rig control error message box you 
can click "Show Details..." and then double click the details and then 
use CTRL+C to copy them to the clipboard.

It sounds like the USB connection to the rig is being lost as you appear 
to be losing both the audio devices and the CAT virtual serial port. RFI 
is a likely cause, have you tried reducing RF power to minimum or using 
a dummy load for a Tx test.

73
Bill