Hi Bill,
This is a minor issue —
In MSK144 mode (perhaps in JTMSK as well), the time labels on the fast graph
seem to have an accumulating error such that near the end of a 30s record the
offset between the displayed time and real time is significant - something like
0.5s or more. The accumulating error can be seen in the attached screenshot
showing a 15s file that was generated by msk144sim - note that the early pings
start at the second marks, but by the end of the record the pings appear to
start about a quarter second late. The time error becomes even more apparent in
a 30s record, such that the time stamps for pings that occur after, say, 20s
are off by more than the duration of the ping.
Steve k9an
------------------------------------------------------------------------------