On 18/08/2016 13:37, Erwin Serle wrote:
My setup works for wspr.exe 4.0
It does not work from the same laptop, same configuration, same
hamlib, same radio etc for wsjt-x 1.6.0 or 1.6.1
When I try this the LDG Z817 starts to click click-click, click
click-click, etc without stopping.
When I take out the LDG Z817 CAT to the radio works.
So I wrote to LDG support with the issue description and they came
back with: This appears to be a software issue.
How can I further investigate the issue? Have others experienced the
same or like issues?
Hi Erwin,
it would appear that the LDG is unhappy with one or more of the CAT
commands being sent by WSJT-X. The FT-817 CAT command set is not very
complex. The first thing I would try is varying the WSJT-X CAT poll rate
and see if the relay clicking is synchronized with polling.
73
Bill
G4WJS.
------------------------------------------------------------------------------