On 22/09/2017 10:33, Francisco Jiménez-Martín Sánchez wrote:
the frequency display in WSJT-X remains in red and the frequency selector appears empty.

Hi Fran,

the defect is that the working frequencies table gets corrupted if you upgrade from WSJT-X v1.8.0 RC1, there is nothing wrong with CAT control. Reset the working frequencies by going to "Settings->Frequencies", right-click the "Working Frequencies" table and click "Reset". This is a one-time operation so long as you do not revert to RC1 again, as noted in the RC2 release notice.

73
Bill
G4WJS.


------------------------------------------------------------------------------