On 21/10/2017 20:54, Richard Futrell wrote:
#
Exact sequence of steps required to reproduce the problem - Transmit
about 2 or 3 times and the errors hamlib error: communication bus
error while getting current vfo frequency occurs.
#
Rig Information - IC-746
Hi Richard,
the most common cause of that error with Icom rigs is that "CI-V
Transceive Mode" is enabled on the rig. Hamlib requires that CI-V
Transceive mode is disabled for reliable CAT communications. Other
software should not be impacted apart from a small number of
applications that only work with "CI-V Transceive Mode" enabled.
73
Bill
G4WJS.
------------------------------------------------------------------------------