On 20/12/2017 13:43, Lou Crocker wrote:
Observations:

On selecting Enable Tx in Echo mode, the program keys the rig repeatedly as expected for several cycles, perhaps from 10 s to a minute. Then one of three things happens: 1) the program stops transmittting without an error message, 2) the program stops and produces an error message "Rig Control Error" and under details, "Hamlib error: Communication bus collision while setting frequency", 3) the program stops with a similar error message but details "Hamlib error: Protocol error while setting frequency".

Hi Lou,

make sure that you have "CI-V Transceive Mode" disabled in your rig's menu.

73
Bill
G4WJS.


------------------------------------------------------------------------------