On 20/12/2017 13:43, Lou Crocker wrote:
Observations:
On selecting Enable Tx in Echo mode, the program keys the rig
repeatedly as expected for several cycles, perhaps from 10 s to a
minute. Then one of three things happens: 1) the program stops
transmittting without an error message, 2) the program stops and
produces an error message "Rig Control Error" and under details,
"Hamlib error: Communication bus collision while setting frequency",
3) the program stops with a similar error message but details "Hamlib
error: Protocol error while setting frequency".
Hi Lou,
make sure that you have "CI-V Transceive Mode" disabled in your rig's menu.
73
Bill
G4WJS.
------------------------------------------------------------------------------