5-5-2018 WSJT-x v1.9.0-rc4 r8642 Error report:
While operating MSK144 on 6 meters - working a CQ calling station,
W7JLC, I received a signal report. My system then sequenced correctly -
sending him back a report "R+17." Shortly thereafter, W7JLC began
working another station and when he sent that station "RR73", my
automatic sequencer moved to the end of the line, i.e., to next
automatically calling "CQ N6PAW CM88." The error here is twofold: (1) my
sequencer should have not shifted - should have continued with "R+17";
and (2) the next in sequence appropriate message should have been "W7JLC
N6PAW 73."
In summary: It appears that as I was working W7JLC and he sent a message
containing "73" the program failed to verify that the "73" was meant for
me, and then mistakenly sequenced to the bottom: into CQ call mode.
------------------------------------------------------------------------------