Hi! Yes, TO19A F/H is quite a confusion. As nonstandard call, they can not send proper report. Luckily, my call is short enough, so I get -1? report.
190502_111445 21.078 Tx FT8 0 0.0 1710 <TO19A> S52D JN76 190502_111500 21.078 Rx FT8 0 0.1 690 S52D TO19A -1 190502_111515 21.078 Tx FT8 0 0.0 690 <TO19A> S52D R+00 190502_111530 21.078 Rx FT8 2 0.1 510 S52D RR73; PA3ANF <TO19A> -18 Funny, while normal answer is not OK, like: 190502_111230 21.078 Rx FT8 7 0.1 510 EA1AHY TO19A 190502_111230 21.078 Rx FT8 7 0.1 570 PA3ANF TO19A 190502_111230 21.078 Rx FT8 7 0.1 630 JG1IGX TO19A 190502_111230 21.078 Rx FT8 6 0.1 690 OK2LC TO19A + 190502_111230 21.078 Rx FT8 6 0.1 750 IW6DGJ TO19A All missing reports. A lot of HAMs were lost, so RR73 messages were rare. RR73 + report is OK. Note: I tuned 200 Hz below nominal QRG to get their signal more into audio passband. Some suggestions: . 9A2AA/FR should work fine. - limit number of streams, thus forcing more RR73 messages As a side note, small nuisance for hounds: If I click "P52D RR73; PA3ANF <TO19A> -18 "to get their call, WSJTX 2.0.1 selects RR73 not TO19A as DX call. It took me a while to realize I am calling wrong call. Best 73, sretno Iztok, S52D [http://psn.sdn.si/ts/neo-plus-naj-samopodpis_345x185.jpg] <https://neo.io/info/paketi?utm_source=mail_podpis> Pravni pogoji / Legal disclaimer Telekom Slovenije, d.d., Ljubljana <http://www.telekom.si/disclaimer> _______________________________________________ wsjt-devel mailing list wsjt-devel@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/wsjt-devel