Hi all,
If I understand well, the "Rig" setting uses 2 VFO's which are set to
different frequencies, if necessary and the "Fake It" setting uses only
one VFO which frequency is changed if necessary.
My observation is that some rigs, having more than one VFO, have the
ability to be used with the "Rig" and the "Fake It" settings, but the
switching time is very different. Often, when using "Rig", the switching
time becomes larger, even too large or, at least, marginal. This
behaviour has been observed with the ICOM IC-725 and the Yaesu FT-2000.
How often does my observation apply to other rigs ? Is this difference
in the switching time only related to the rig itself or are there
additional reasons ?
Best wishes,
Claude (DJ0OT)