Hi, I don't see this behaviour when sending a TX5 (at low power into a
dummy load of course!) from my own call to my own call with /P added.
If I try the same but with /MM instead of /P I don't see the behaviour
either, but the /MM is not transmitted and is also not shown anywhere in
the UI apart from the TX5 box.
W10 64 Pro, latest updates
Alan G0TLK
On 24/12/2021 07:48, Rich - K1HTV via wsjt-devel wrote:
I have run into a problem with WSJT-X 2.5.3 when transmitting a TX5
message to any station with a "/" followed by /MM or /P and probably
other characters. I'm running the Win 64 bit version on a Windows 10
computer with the latest updates.
After transmitting the TX5 message, the receive cycle starts and runs
for 11 seconds. At that point the clock in the lower left corner stops
and a few lines of decoded data is displayed, then the program ends.
The problem ican be reproduced.
A jt9.exe process is left running, which must be deleted with Task
Manager before WSJT-X can be started again.
The issue only occurs with stations with a forward slash in the
callsign. I tried using a non-standard callsign such as 3DA0XXX, with
no problem, only with calls with slash.
I've gone back to WSJT-X Version 2.5.2 and ran the same tests without
the program crashing after a TX5 message with a forward slash in the call.
73,
Rich - K1HTV