(Flex 3.2.39, WSJT-X 2.5.4, W11 )
I hadn't looked at wsjtx_syslog.log in a few weeks ( since upgrade from
2.5.3 to 2.5.4 )
Today I noticed that the log contains RIGCTL warning message for each
FT8 cycle.
[RIGCTRL][2022-01-17 20:08:10.565987][04:16:35.503896][warning]
kenwood_get_split_vfo_if(1583): unknown rxVFO=None
Despite fact that there is a warning, everything seems to be operating
normally. The warnings did not occur in 2.5.3.
I have wsjt-x configured to use Flex 6xxx as rig type and split set to
None.
The per cycle SSDR_CAT traffic for the port looks like
2022-01-17 14:33:04.060 TCP 26004 [rcvd]: IF;
2022-01-17 14:33:04.061 TCP 26004 [sent]:
IF000101360000010+0000000000090000000;
2022-01-17 14:33:04.081 TCP 26004 [rcvd]: FA;
2022-01-17 14:33:04.082 TCP 26004 [sent]: FA00010136000;
2022-01-17 14:33:04.101 TCP 26004 [rcvd]: MD;
2022-01-17 14:33:04.102 TCP 26004 [sent]: MD9;
2022-01-17 14:33:04.122 TCP 26004 [rcvd]: ZZFI;
2022-01-17 14:33:04.123 TCP 26004 [sent]: ZZFI01;
2022-01-17 14:33:04.142 TCP 26004 [rcvd]: IF;
2022-01-17 14:33:04.143 TCP 26004 [sent]:
IF000101360000010+0000000000090000000;
Again the operation seems normal except the log fills up rapidly.
AL, K0VM
_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net