Hi Paul,

In FST4W mode, the multiple banking percentages triggered by negative NB 
settings are tried for all signal candidates within the RxFreq +/- FTol range.

Steve, k9an

> On Dec 6, 2024, at 9:46 AM, Paul N1BUG FN55mf via wsjt-devel 
> <wsjt-devel@lists.sourceforge.net> wrote:
> 
> Please forgive my ignorance. Reviewing the release notes and reading the
> manual have not resolved my uncertainty on this.
> 
> I am using WSJT-X 2.7.0-rc7.
> 
> Sec. 6.5 FST4 of the user manual says "To save time, the multiple
> blanking percentages triggered by negative NB settings are tried only
> for signal candidates located near (within +/- 20 Hz) of the Rx
> frequency setting."
> 
> Sec. 6.6 FST4W does not specify over what frequency range multiple NB
> levels will be tried. Will multiple NB levels be tried over the entire
> Rx Freq +/- F Tol range?
> 
> Thanks,
> 
> Paul N1BUG
> (returning to 2200m)
> 
> 
> _______________________________________________
> wsjt-devel mailing list
> wsjt-devel@lists.sourceforge.net
> https://lists.sourceforge.net/lists/listinfo/wsjt-devel



_______________________________________________
wsjt-devel mailing list
wsjt-devel@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/wsjt-devel