Issues to sync correctly with page load in watir1.6.7
-----------------------------------------------------

                 Key: WTR-466
                 URL: http://jira.openqa.org/browse/WTR-466
             Project: Watir
          Issue Type: Bug
          Components: Wait
    Affects Versions: 1.6.7
         Environment: Win XP IE6, IE7
            Reporter: Aliaksandr
            Priority: Major


Hi, 

We have recently updated our test environments to watir1.6.7 and our 
scripts start to fail waiting for page to be fully loaded. Failures 
happen when a script tries to access certain html elements on the page 
while it is actually still loading. 

We were able to figure out the cause of this behaviour. It is due to the 
READYSTATE_INTERACTIVE state was added as the state to determine 
browser load is complete: 

ie-process.rb: 
# Used internally to determine when IE has finished loading a page 
READYSTATE_INTERACTIVE = 3 

Wondering, what was the reason to include it? 

This is an urgent issue for us (we have quite a few physical and virtual client 
boxes for automation execution, which need a fix), so very appreciate your 
help. For now we have to downgrade to watir1.6.5 throughout our test 
environment.


Best Regards,
Alex

-- 