I just checked in a change to increase the timeouts on the rbeacon and rvitals commands. Regrettably, SNMP commands involving LED requests can take up to 5 minutes to be fulfilled by the AMM, during which the AMM will not respond to other SNMP requests. This is under investigation. Non-snmp interfaces are not impacted by this behavior.
From: Arif Ali <[email protected]> To: "Mailing list, xCAT" <[email protected]>, Date: 11/01/2011 06:46 PM Subject: [xcat-user] Bladecenter rbeacon issue Hi all, not sure if anyone is aware of this. It seems that the rbeacon on the bladecenter causes the bladecenter AMM to become unresponsive for about 5-10 seconds. rpower group stat works every single time, but rbeacon group on, would hang on the initial nodes and work ok on the rest. But cause timeout issues on it Is there anything I need to be aware of in this situation wrt to snmp or ssh to the AMM -- Arif Ali catch me on freenode IRC, username: arif-ali ------------------------------------------------------------------------------ RSA® Conference 2012 Save $700 by Nov 18 Register now! http://p.sf.net/sfu/rsa-sfdev2dev1 _______________________________________________ xCAT-user mailing list [email protected] https://lists.sourceforge.net/lists/listinfo/xcat-user