Video but I can check rcons and report back.

Sent from my Verizon Wireless 4G LTE DROID


Jarrod Johnson <[email protected]> wrote:


Watching through video or rcons?

On Nov 17, 2015 6:26 PM, "Julius, Chad" <[email protected]> wrote:

All,



My first time installing xCAT and everything seemed to be working great until I 
boot the nodes.  They pull the proper DHCP addresses that I have assigned to 
them when I defined the nodes and they don't error out but instead sit at 
trying to load pxelinux.cfg/(nodename).   I don't think it is stuck on that 
because the message log shows it is past that.



Looking at node01(AC1D0A65) /var/log/messages shows:



Nov 17 15:24:31 csm2 in.tftpd[4871]: RRQ from 172.29.10.101 filename pxelinux.0

Nov 17 15:24:31 csm2 in.tftpd[4872]: RRQ from 172.29.10.101 filename 
pxelinux.cfg/406a156f-ea4c-b601-27f5-00145ef51424

Nov 17 15:24:31 csm2 in.tftpd[4873]: RRQ from 172.29.10.101 filename 
pxelinux.cfg/01-00-14-5e-f5-14-24

Nov 17 15:24:31 csm2 in.tftpd[4874]: RRQ from 172.29.10.101 filename 
pxelinux.cfg/AC1D0A65

Nov 17 15:24:31 csm2 in.tftpd[4875]: RRQ from 172.29.10.101 filename 
xcat/osimage/sles113compute/linux

Nov 17 15:24:31 csm2 in.tftpd[4876]: RRQ from 172.29.10.101 filename 
xcat/osimage/sles113compute/initrd



I assume the node is communicating with the management node and trying to 
retrieve the file.



The contents of the pxelinux.cfg file (AC1D0A65) are (before it was populated 
with the genesis kernel etc... but after defining the osimage it change them to 
what is below):



#install sles11.3-x86_64-compute

DEFAULT xCAT

LABEL xCAT

KERNEL xcat/osimage/sles113compute/linux

APPEND initrd=xcat/osimage/sles113compute/initrd quiet 
autoyast=http://172.29.10.1:80/install/autoinst/node01 
install=http://172.29.10.1:80/install/sles11.3/x86_64/1 netdevice=eth0  console

=tty0 console=ttyS0,115200n8r

  IPAPPEND 2



Very simple setup, using an IBM x3455 server as the management node and 3 LS21 
blades in a BladeCenter H enclosure connected to the same switch, all set in 
the same vlan.  I chose SLES 11.3 to mimic our production environment even 
though it is outdated but it affords me a test area should something go wrong 
in production.  I can add more nodes etc... as we have many more blade centers 
but I just wanted to get the basics down before I went all in.  My background 
isn't in HPC, far from it, however I am trying to learn.



I have let the nodes sit for some time and nothing is happening.   I have been 
following the 
https://sourceforge.net/p/xcat/wiki/XCAT_iDataPlex_Cluster_Quick_Start/#configure-xcat
 guide and it has served me well but I am kind of stuck.  They seem to be doing 
what they are supposed to be doing but won't go past this.  Any thoughts?  I 
assume it must be something I missed.  Are there other logs I need to look into?



I can send more info if needed.



Thank you,



Chad


------------------------------------------------------------------------------
Give your users amazing mobile app experiences with Intel XDK.
Use one codebase in this all-in-one HTML5 development environment.
Design, debug & build mobile apps & 2-D/3-D games for multiple OSs.
Then get your creation into app stores sooner, with many ways to monetize.
http://pubads.g.doubleclick.net/gampad/clk?id=254741551&iu=/4140
_______________________________________________
xCAT-user mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/xcat-user

Reply via email to