>>> On 23.03.17 at 12:47, <anthony.per...@citrix.com> wrote:
> When the divide value change, uptade the timer according to the new
> value, and keep the Counter Register (TMCCT) value the same between
> before and after the divisor change.

General and formatting comments given on patch 1 apply here too,
the logic looks okay assuming the intended / observed behavior is
that on-the-fly updates to the register take immediate effect on all
other functionality.