On 19.02.20 18:25, Igor Druzhinin wrote:
During CPU down operation RCU callbacks are scheduled to finish
off some actions later as soon as CPU is fully dead (the same applies
to CPU up operation in case error path is taken). If in the same grace
period another CPU up operation is performed on the same CPU, RCU callback
will be called later on a CPU in a potentially wrong (already up again
instead of still being down) state leading to eventual state inconsistency
and/or crash.
In order to avoid it - flush RCU callbacks explicitly upon finishing off
the current operation.
Signed-off-by: Igor Druzhinin <igor.druzhi...@citrix.com>
Reviewed-by: Juergen Gross <jgr...@suse.com>
Juergen
_______________________________________________
Xen-devel mailing list
Xen-devel@lists.xenproject.org
https://lists.xenproject.org/mailman/listinfo/xen-devel