On Fri, 2006-07-21 at 10:46 +0200, ROSSIER Daniel wrote:
> 
> Hi Philippe,
> 
> > -----Message d'origine-----
> > De : Philippe Gerum [mailto:[EMAIL PROTECTED]
> > Envoyé : jeudi, 20. juillet 2006 22:50
> > À : ROSSIER Daniel
> > Cc : [email protected]
> > Objet : Re: [Xenomai-help] Priority inversion
> > 
> > On Thu, 2006-07-20 at 15:14 +0200, ROSSIER Daniel wrote:
> > >
> > > Hi all,
> > >
> > > Attached, another tricky piece of code.
> > >
> > > We actually try to exhibit a priority inversion by using the semaphore
> > (which does not implement the priority inheritance protocol).
> > >
> > > We have the three following tasks:
> > >
> > > - meteoDataAcquisition: acquiring the mutex, spinning 10ms, releasing
> > the mutex / priority 1 / delayed at 18ms, and then activated with a
> > frequency of 1000 ms from its first activation (so normally, more or less
> > activated at 1018, 2018, 3018, etc.)
> > >
> > > - busManagement: acquiring the mutex, spinning 5 ms, releasing the mutex
> > / priority 10 / period of 20 ms.
> > > - comHandling: just spinning 10ms, period of 20 ms.
> > >
> > > So, the worst case would be when the meteoDataAcquisition acquired the
> > mutex right before the busManagement, so we can say that the highest
> > priority task will be delayed of 10ms at the worst; we put an alarm of
> > 30ms, then no alarm will raise up; and indeed, it works like that.
> > >
> > > Doing the same stuff with the semaphore - just change WITH_MUTEX to 0 -
> > should theoretically lead to an alarm since the comHandling will take the
> > hand, delaying the busManagement over 30ms. Here comes the problem: if we
> > leave the alarm at 30ms, the alarm raises up, as expected. But, if we
> > change the alarm to 31ms, there is no alarm anymore... and we do not
> > understand why? Normally we should see some alarms for some values from 31
> > to 35ms, since comHandling spins during 10ms. Mytery...
> > >
> > > Normally, the task meteoDataAcquisition is aperiodic, and activated on
> > the basis of an IRQ. In order to simulate that, we put the task with a
> > delay of 18ms (yes, that's the reason of 18 ;-)), activated each second
> > (therefore causing the priority inversion systematically). But nothing
> > happens! the system runs, but no alarm raises up with
> > 
> > With some help from the simulator,
> > http://download.gna.org/xenomai/screenshots/simulator.png
> > here is the timeline of your example:
> > 
> > [sys_date*] [task]  [alarm_setup*]
> > 0           com
> > 10          bus     15
> 
> Given that the bus prio is 10, and com prio is 5, why the bus doesn't 
> interrupt the com task right after its start in the init_module. I can 
> imagine that the com task has a bit time to execute some instructions, but 
> never spending more than 1-2ms before the bus starts. Is there a problem in 
> the pod initialization?
> 

Precisely because the task underlying the init_module() routine has a
lower priority than the com task, so there is no way for the bus task to
be started by the init context before the com task relinquishes the CPU
by calling rt_task_wait_period(). The scheduling is then:

init    (pri -1)
        start com
com     (pri 5)
        spin
        wait_period
init    (pri -1)
        start bus
bus     (pri 10)

> > 18          mto
> > 20          bus     35
> > loop:
> > 20          com
> > 40          bus     45
> 
> This behaviour is not correct. The task mto holds the mutex when prempted by 
> the bus; the bus is using the same mutex and should not be able to run 
> anymore, giving the hand to the mto task in case of mutex, or giving the hand 
> to the the com, using the sema.
> 

Nope, the mto task has reached rt_task_wait_period() when the bus task
resumes, so the sema4 is free. You should really try running your
example over the event-driven simulator, it would be much easier for you
to grasp the actual dynamics of this quite tricky code. Even if you
don't trust the simulator a priori, you could just analyze what it says
the behaviour of your application is, and make your opinion. I've
tracked it a few times already, and so far, everything is ok.

> Well actually, we found this morning something very strange. It seems that 
> the mutex/sema can be acquired twice, before releasing it! We simply added a 
> printk() at the beginning of the critical section (with timestamp), and 
> noticed that two P(), or two mutex_lock() were performed before the release.
> 

Nothing strange here: native API mutexes are recursive by construction.
Other threads but the current owner would block trying to acquire it.
As for the timestamps, how do you obtain them?

> We think that there is an issue with the use of TM_INFINITE as argument in 
> the locking functions. We didn't test any other args.
> > 45          com
> > 60          bus     65
> > 65          com
> > 80          bus     85
> > 85          com
> > 100         bus     105
> > 105         com
> > 118         mto
> > 120         bus     135
> > jump loop
> > 
> > (*) system and alarm setup dates are expressed in relative ticks since
> > the application startup.
> > 
> > Given that there is never more than 30 ticks between two alarm setups in
> > this timeline (i.e. between ticks #105 and #135), the result you got
> > looks correct.
> > 
> > --
> > Philippe.
> > 
> 
> 
> 
> Daniel
> 
-- 
Philippe.



_______________________________________________
Xenomai-help mailing list
[email protected]
https://mail.gna.org/listinfo/xenomai-help