Dear Xenomai Developers/Users, the results of the measurements with irqbench/irqloop show time differences of around 1 us between the different latencies observed. I have chosen an interrupt frequency of 1 ms. An example of my results is located at:
http://www-user.tu-chemnitz.de/~franm/Xenomai_IRQ_Handler.png. Where do the discrete distances between the results come from? It looks as if it is always around 1 us. Why aren't the results distributed continuously? By the way, my bucket_size wasn't 1 us, rather it was 1 ns, so actually without any buckets. Regards, Markus Franke _______________________________________________ Xenomai-help mailing list [email protected] https://mail.gna.org/listinfo/xenomai-help