Some Synaptics image sensors report samples at less than 80 Samples/sec. Thus, the inter-sample gap is longer than 13 ms (more like 17-25 ms).
With a 13ms timeout, every sample was processed twice: 1) Once when ReadHwState() returned valid data. 2) 13ms later, when the scheduled timer would expire. The value 50ms is chosen arbitrarily higher than the expected slowest trackpad reporting interval, but short enough not to be noticeable by a human user. Signed-off-by: Daniel Kurtz <[email protected]> --- src/synaptics.c | 2 +- 1 files changed, 1 insertions(+), 1 deletions(-) diff --git a/src/synaptics.c b/src/synaptics.c index 56ce725..0b2d7a1 100644 --- a/src/synaptics.c +++ b/src/synaptics.c @@ -1870,7 +1870,7 @@ ComputeDeltas(SynapticsPrivate *priv, const struct SynapticsHwState *hw, /* to create fluid edge motion, call back 'soon' * even in the absence of new hardware events */ - delay = MIN(delay, 13); + delay = MIN(delay, 50); if (priv->count_packet_finger <= 3) /* min. 3 packets, see get_delta() */ goto skip; /* skip the lot */ -- 1.7.3.1 _______________________________________________ [email protected]: X.Org development Archives: http://lists.x.org/archives/xorg-devel Info: http://lists.x.org/mailman/listinfo/xorg-devel