On Fre, 2012-05-04 at 18:29 +0200, Michal Srb wrote: 
> The swapped implementation of DRI2Connect is always responding with empty
> device and driver values. However the response was only prepared and never
> sent (also had undefined .type member), causing e.g. glxinfo get stuck waiting
> for response when started remotely from machine with different endianity.
> 
> Signed-off-by: Michal Srb <[email protected]>
> Reviewed-by: Jeremy Huddleston <[email protected]>

Tested-by: Michel Dänzer <[email protected]>

This should also go to stable trees.


-- 