Hi Folks--

> Are you using the xplor-nih in python mode?  If so, I'd suggest that you
> use protocol.AddUnknownAtoms() to add the MSC ligand.  HBUILD is unable to
> handle adding heavy atoms, and that's the problem that you are seeing.
> Addunknownatoms() basically gives random positions to every unknown atom
> and then refines based on the covalent geometry.
> 
> When I was doing this, I also found that I needed to use
> protocol.FixupCovalentGeometry() to really get things right.  Your mileage
> may vary.
> 

this seems like good advise to me. To be precise, the necessary python
statements are

import protocol
protocol.addUnknownAtoms()
protocol.fixupCovalentGeom()

be aware that fixupCovalentGeom  will slightly modify the initial input
coordinates. Please let us know if this is unacceptable, and I will
suggest an alternative approach.